UPDATED 1 Sept: The EI library in London is temporarily closed to the public, as a precautionary measure in light of the ongoing COVID-19 situation. The Knowledge Service will still be answering email queries via email , or via live chats during working hours (09:15-17:00 GMT). Our e-library is always open for members here: eLibrary , for full-text access to over 200 e-books and millions of articles. Thank you for your patience.

Fixed-bed technology purifies rich gas with H2S, Hg. E.F. Rhodes, P.J. Openshaw and P.J.H. Carnell. OGJ, 31 May 1999, 97(22), 58--63.

Details are given of the treatment of dense-phase natural gas with fixed-bed technology which has been proven effective and economic at the North Sea terminal for Central Area Transmission System (CATS). The central Graben development is described, and the dense-phase operation, testing, mercury removal, and material handling is examined. The gas processing plant is discussed and LPG fractionation, and operating experience are described. 4 refs.